140 mm Wide x 80 mm High
Code: T1
Uncorrected Output: 204 watts/metre
1 x 35 mm x 75 mm Finned Element
|

250 mm Wide x 80 mm High
Code: T2
Uncorrected Output: 387 watts/metre
2 x 35 mm x 75 mm Finned Element
|

150 mm Wide x 150 mm High
Code: T3
Uncorrected Output: 520 watts/metre
1 x 75 mm x 75 mm Finned Element
|
|

250 mm Wide x 150 mm High
Code: T4
Uncorrected Output: 970 watts/metre
2 x 75 mm x 75 mm Finned Element
|

225 mm Wide x 200 mm High
Code: T5
Uncorrected Output: 655 watts/metre
1 x 108 mm Finned Element
|

350 mm Wide x 200 mm High
Code: T6
Uncorrected Output: 1294 watts/metre
2 x 108 mm Finned Element
|
|

250 mm Wide x 225 mm High
Code: T7
Uncorrected Output: 1605 watts/metre
4 x 75 mm x 75 mm Finned Element
|
 
350 mm Wide x 300 mm High
Code: T8
Uncorrected Output: 2193 watts/metre
4 x 108 mm Finned Element
|

|
Important Notes:
Where downdraft from glazing is the only concern the Trench Heater width can be reduced by 25 mm. The Finned element is moved to the room side to allow the down draft from the glazing to be drawn into the heater. (The 150 mm Wide Trench Heater cannot be reduced by more than 20 mm). The above centralised Finned elements will draw cool air from both sides (floor and wall/glazing) so optimising the available cool air for heating.
|